CIFM-88 Coriolis Flow Meter for High Purity Applications Unmatched Durability for Aggressive Chemistries

The CIFM-88 DuraMassFlow Coriolis Flow Meter utilizes advanced sensors that simultaneously measure mass flow, density and temperature with an exceptional accuracy of ±1%. The built-in LCD display provides real-time data on flow rate, totalized flow, temperature, and density for enhanced process visibility.

Featuring a patented design with unmatched durability for chemical and industrial applications, it is an ideal solution for measuring aggressive acids and alkalis in chemical and industrial processes. The CIFM-88 Coriolis Flow Meter is encased in a rugged stainless-steel housing to ensure it meets IP65 and CE standards. Constructed with PFA-wetted materials, it offers improved durability against corrosive chemicals.

Designed to deliver long-term performance in the most demanding industrial environments, the CIFM-88 Series PFA Coriolis Mass Flow Meter ensures precise process control, minimizes operational costs and maximizes uptime. It is the ideal choice for efficiency and reliability in industrial applications.

Features

  • Exceptional accuracy of ±1% due to patented Coriolis flow meter technology
  • Multivariable measurement: mass, flow, density, and temperature
  • Suitable for aggressive acids and alkalis, due to PFA material that offers exceptional durability against corrosive chemicals
  • No need for upstream and downstream straight pipe runs
  • High flow measurement turndown
  • Mass flow measurements are independent of chemical properties
  • Accuracy is unaffected by flow regime (e.g., laminar or turbulent flow) or variations in the flow velocity profile
  • Sensors can operate and measure fluids in two-phase flow conditions with gas volumetric void fractions up to 30%
  • Encased in rugged stainless-steel housing that meets IP65 and CE standards
  • Built-in 4-line LCD panel, provides real-time data on flow rate, totalized flow, temperature and density

Applications

  • Chemical Processing
  • Pharmaceutical Manufacturing
  • Food and Beverage Production
  • Pulp and Paper Industry
  • Wastewater Treatment

Specifications

Measurement Specifications

Measurement Range 1/4” size: 50–1,500 g/min
3/8” size: 200–4,000 g/min
1/2” size: 1000–25,000 g/min
Accuracy
1/4" size: ±1% of flow rate between 150–1500 g/min; for flow rates below 150 g/min ±1% of flow rate ±2 g/min

3/8" size: ±1% of flow rate between 400–4000 g/min; for flow rates below 400 g/min ±1% of flow rate ±3 g/min

1/2” size: ±1% of flow rate between 2,500–25,000 g/min; for flow rates below 2,500 g/min ±1% of flow rate ±20 g/min

Physical Specifications

Process Connections 1/4”, 3/8”, 1/2” Flare or Pillar connection
Wetted Material Perfluoroalkoxy PFA
Enclosure Material SS 304

Electrical Specifications

Transmitter Integral with flow sensor
Supply Voltage 24 V DC ±10%
Output 4–20 mA Current Loop, Frequency Output 0–10 kHz
Digital Communication Modbus RS485
Display Local LCD with flow total reset and flow zero keys

Environmental Specifications

Ambient Temperature
0–50°C
Fluid Temperature
18–50°C
*for 1/2” size: 18–45°C
Operating Pressure 80 psig (max.)
Area Classificatio For use in safe area
Ingress Protection IP65