When additional blood flow data is needed during an extracorporeal procedure, the SonoTT™ aQuila provides a flexible, stand-alone method for measuring it.

The system combines a monitor with up to two SonoTT™ Clamp-On flow sensors, allowing blood flow to be measured and analyzed simultaneously at additional points within the extracorporeal circuit. This provides greater visibility into flow at locations such as distal leg perfusion, that the host device does feature. Other applications include apheresis, hemodialysis, ECMO with more than two access cannulas and heart-lung machine procedures.

SonoTT™ aQuila

The SonoTT™ aQuila is a stand-alone MDR Class I medical device designed to provide additional blood flow measurement during extracorporeal procedures. Compatible SonoTT™ Clamp-On flow sensors attach around the outside of the tubing, providing non-invasive measurement without direct contact with the fluid.

Features and Benefits

Additional Blood Flow Measurement in Clinical Applications

  • Early detection of complications or anomalies that may occur during an extracorporeal procedure, such as clogged filters or inadequate blood flow
  • Quicker detection of changes in the current flow rate that may indicate the deterioration of the circulation condition

Reliable and Flexible Measurement

  • Simultaneous measurement with up to two sensors
  • Broad portfolio of sensor sizes for use across different medical applications
  • IP42 protection class without power supply

Flexible Mounting and Positioning

  • Compact stand-alone device
  • Approximate weight of 2.3 kg
  • Standard VESA 75 × 75 mounting
  • Optional holder configurations for flexible positioning

Display and Interface

  • Graphical and numerical visualization
  • 10.1-inch touchscreen
  • Suitable for use while wearing gloves
  • User interface for data recording and export

Compatible SonoTT™ Clamp-On Sensors

  • Compatible with commonly used medical tube sizes
  • Suited for extracorporeal applications
  • Clamped around the tubing with no direct contact with the fluid

Technical Data — Compatible Sensor and Tube Dimensions

SENSOR SIZE ID [INCH] WT [INCH] OD [INCH] ID [MM] WT [MM] OD [MM]
1/8" X 1/16" 1/16 3/32 1/4 1.59 2.38 6.35
1/8" X 1/16" 1/8 1/16 1/4 3.18 1.59 6.35
11/64" X 3/64" 11/64* 3/64* 17/64* 4.30 1.25 6.80
3/16" X 1/16" 1/8 3/32 5/16 3.18 2.38 7.94
3/16" X 1/16" 3/16 1/16 5/16 4.76 1.59 7.94
1/4" X 3/32" 1/4 3/32 7/16 6.35 2.38 11.11
1/4" X 3/32" 5/16 1/16 7/16 7.94 1.59 11.11
1/4" X 1/16" 3/16 3/32 3/8 4.76 2.38 9.53
1/4" X 1/16" 1/4 1/16 3/8 6.35 1.59 9.53
3/8" X 1/16" 1/4 1/8 1/2 6.35 3.18 12.70
3/8" X 1/16" 3/8 1/16 1/2 9.53 1.59 12.70
3/8" X 3/32" 3/8 3/32 9/16 9.53 2.38 14.29
1/2" X 3/32" 1/2 3/32 11/16 12.70 2.38 17.46

* Approximate inch fractions